Difference between revisions of "For scRNA-seq"
Jump to navigation
Jump to search
(Continue from the dissociation protocol)
(Created page with "= scRNA-seq = ---- <li>(Continue from the [[|dissociation protocol]])</li> *After 30um filter cup, immediately filter through 10um filter cup Resuspend the cell pellet with 15...") |
(No difference)
|
Revision as of 22:23, 18 July 2022
scRNA-seq
- After 30um filter cup, immediately filter through 10um filter cup
Resuspend the cell pellet with 150-300uL AMEM(0) depending on the size of the pellet.
- Immediately sort the cells into 1.5mL tube with 700uL AMEM(0).
- Normally we use F02 sorter because it has lasers for both GFP and mCherry.
- Note the FACS count.
- Centrifuge 300xrcf, 20 degree, 5 minutes. Remove supernatant.
- The sample is ready for downstream applications: